[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15034056
Date Manufactured	05/02/2013
Lot	WO0000109275186
DesignStudio ID	21703
Target Plexity	100
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
ABCG2	NM_004827	6819840	15	14	Homo sapiens	hg19	4	89015737	89013532	AATGCAACAGGAAACAATCCTTGTAAC	1	TGTACTGGCGAAGAATATTTGGTAAAGC	1	MINUS	ILLUMINA	1.955	false	FromReportXYZ;FromStudyXYZ
ACTC1	NM_005159	6632116	5	4	Homo sapiens	hg19	15	35084296	35083483	CCTGAGACACTCTTCCAGCCCTCCTT	9	TGGCATCCATGAAACAACTTACAATAGC	2	MINUS	ILLUMINA	1.85	false	FromStudyXYZ
ADAR	NM_015841	6608567	6	5	Homo sapiens	hg19	1	154569287	154562881	ACCAGTCCGGACCTCCTCACGA	1	GTTTACCAAGCAAAAGTTGGGGGTC	1	MINUS	ILLUMINA	1.317	false	
ALDH1A1	NM_000689	6692381	1	0	Homo sapiens	hg19	9	75567859	75555153	TCCTACTCACCGATTTGAAGATTCAAT	2	GAATGGCATGATTCAGTGAGTGGCAA	1	MINUS	ILLUMINA	1.951	false	
ALDH2	NM_000690	6629677	3	4	Homo sapiens	hg19	12	112223120	112227670	TGGATTTGGACATGGTCCTCAAATGTC	1	TAAGTACCACGGGAAAACCATCC	2	PLUS	ILLUMINA	1.626	false	
APC	NM_001127510	6843533	3	4	Homo sapiens	hg19	5	112102075	112102916	CTGGACAGATTGATTTATTAGAGCGTC	1	GCTTAACTTAGATAGCAGTAATTTCCCTGG	1	PLUS	ILLUMINA	1.769	false	
AXIN1	NM_003502	6812087	10	9	Homo sapiens	hg19	16	339443	338246	GGAGCTGCTGACCAAAAAGGGCAGCTA	1	ACTACTTCAAGAAAGTGAGCGACGAG	1	MINUS	ILLUMINA	1.868	false	
BMP1	NR_033403	6706970	13	14	Homo sapiens	hg19	8	22054321	22054794	CAGTTTGACTTCTTTGAGACAGAGGGC	1	CGTGGAGGTGCGCAGTGGACTCACA	1	PLUS	ILLUMINA	1.704	false	
BMP2	NM_001200	6770547	1	2	Homo sapiens	hg19	20	6751083	6758932	AGCCGAGCCAACACTGTGCGCAGCTT	1	TACCAGAAACGAGTGGGAAAACAACC	1	PLUS	ILLUMINA	1.734	false	
BMP3	NM_001201	6598093	1	2	Homo sapiens	hg19	4	81967775	81974527	TGGAGCATGCCAGTTCCCCATGCCAAA	1	TGAAGCCATCAAATCATGCTACCAT	2	PLUS	ILLUMINA	1.765	false	
BTRC	NM_033637	6714783	2	3	Homo sapiens	hg19	10	103221781	103239168	GGAAGATAATACCAGAGAAGAATTCACT	1	GACTCTGCTTAAACCAAGAAACAGT	1	PLUS	ILLUMINA	1.824	false	
CCNA2	NM_001237	6736142	2	1	Homo sapiens	hg19	4	122743566	122742245	GGTCCCTCTTGATTATCCAATGGATGG	1	GTCACCACATACTATGGACATGTCA	1	MINUS	ILLUMINA	1.878	false	
CCND1	NM_053056	6833728	2	3	Homo sapiens	hg19	11	69458729	69462799	GCGCAGACCTTCGTTGCCCTCTGT	2	CCAATCCGCCCTCCATGGTGGCA	7	PLUS	ILLUMINA	1.18	false	
CCND2	NM_001759	6791916	2	3	Homo sapiens	hg19	12	4388053	4398034	ATGCTCAGACCTTCATTGCTCTGTGT	1	CTTTAAGTTTGCCATGTACCCACCGT	1	PLUS	ILLUMINA	1.933	false	
CCNE1	NM_001238	6797467	5	6	Homo sapiens	hg19	19	30308412	30311644	AAAAATGCGAGCAATTCTTCTGGATTGG	1	GTCTATAAACTTCACAGGGAGACCTTT	1	PLUS	ILLUMINA	1.961	false	
CD3D	NM_000732	6784536	4	3	Homo sapiens	hg19	11	118210173	118209939	CAAGCTCTGTTGAGGAATGACCAGGT	1	CTCCGAGATCGAGATGATGCTCAGTA	1	MINUS	ILLUMINA	1.905	false	
CD4	NM_000616	6679411	5	6	Homo sapiens	hg19	12	6925541	6926327	TCAGGAAGTGAACCTGGTGGTGAT	3	CAGCTCCAGAAAAATTTGACCTGTGAG	1	PLUS	ILLUMINA	1.763	false	
CD44	NM_000610	6794802	0	1	Homo sapiens	hg19	11	35160877	35198150	CTGGGGACTCTGCCTCGTGCCGCTGA	1	TGAATATAACCTGCCGCTTTGCAGGT	1	PLUS	ILLUMINA	1.637	false	
CD8A	NM_001145873	6799159	8	7	Homo sapiens	hg19	2	87015651	87013077	CGTGTTTGCAAATGTCCCCGGC	4	AGACAAGCCCAGCCTTTCGGCGAGAT	1	MINUS	ILLUMINA	1.306	false	
CD8B	NM_172101	6743639	2	1	Homo sapiens	hg19	2	87085191	87080208	GCTGACCTTCGGGAAGGGAACTCA	2	TGATTTCCTTCCCACCACTGCCCA	9	MINUS	ILLUMINA	1.45	false	
CDC42	NM_001039802	6816991	2	3	Homo sapiens	hg19	1	22405040	22408252	CACAACAAACAAATTTCCATCGGAATATG	7	CTATGCAGTCACAGTTATGATTGGTGG	6	PLUS	ILLUMINA	1.868	false	
CDH1	NM_004360	6722746	1	2	Homo sapiens	hg19	16	68772278	68835616	CGGCGCCACCTGGAGAGAGGCC	7	GCACCGGTCGACAAAGGACAGCCTATTTT	1	PLUS	ILLUMINA	1.149	false	
CDH2	NM_001792	6781301	14	13	Homo sapiens	hg19	18	25562913	25543466	TATGATGAAGAAGGTGGAGGAGAAGAAG	6	TGCAGCAGCCTGACACTGTGGA	10	MINUS	ILLUMINA	1.426	false	
CDX2	NM_001265	6649231	2	1	Homo sapiens	hg19	13	28539026	28537489	AAGCCGAGCTAGCCGCCACGCT	1	GAACCGCAGAGCAAAGGAGAGGAAAAT	1	MINUS	ILLUMINA	1.363	false	
COL1A1	NM_000088	6730404	50	49	Homo sapiens	hg19	17	48263147	48263002	CACCTACAGCGTCACTGTCGATG	1	CCGGAGCCTGGGGCAAGACAGTGATTGAAT	1	MINUS	ILLUMINA	1.26	false	
COL2A1	NM_001844	6655921	24	23	Homo sapiens	hg19	12	48379701	48379596	CAGGTCAAGATGGTCTGGCAGGT	5	AGCGAGGGCCCAGTGGTCTTGCT	4	MINUS	ILLUMINA	1.117	false	
CREBBP	NM_004380	6633710	1	0	Homo sapiens	hg19	16	3929843	3900997	CTCAGCTCGCCCGGTTTCTCGGCGAAT	1	GTTTGACTTGGAAAATGATCTTCCTGATG	1	MINUS	ILLUMINA	1.661	false	
CTNNA1	NM_001903	6739734	16	17	Homo sapiens	hg19	5	138268375	138269534	CTCGGCGGGGAGCTTGTTGTCTCT	1	ATCCAGGCAGCCAAGAACTTGAT	7	PLUS	ILLUMINA	1.298	false	
CTNNB1	NM_001098210	6833435	0	1	Homo sapiens	hg19	3	41241134	41265540	CGCGGCGGGAGGAGCCTGTTCCCCTGA	1	GGTATTTGAAGTATACCATACAACTGTTT	1	PLUS	ILLUMINA	1.399	false	
CXCL12	NM_001178134	6692620	1	0	Homo sapiens	hg19	10	44880399	44876327	CGTGCTGACCGCGCTCTGCCTCA	4	GAAGCCCGTCAGCCTGAGCTACAGAT	1	MINUS	ILLUMINA	1.346	false	
DHH	NM_021044	6674108	1	0	Homo sapiens	hg19	12	49487997	49485170	GTGGAGCCGACCGCCTGATGAC	1	TTGTAAGGAGCGGGTGAACGCTTT	2	MINUS	ILLUMINA	1.163	false	
DLL1	NM_005618	6782624	1	0	Homo sapiens	hg19	6	170599177	170598881	TGGCGGTGCTCTCGGCCTTGCTGTGT	1	GTGTTCGAACTGAAGCTGCAGGAGTT	1	MINUS	ILLUMINA	1.655	false	
DLL3	NM_203486	6690868	3	4	Homo sapiens	hg19	19	39993669	39994749	ACCGCTCGAGGACGAATGTGAG	1	AGGCTGCAGCCCTGAGCATGGCTTCT	1	PLUS	ILLUMINA	1.242	false	
DNMT3B	NM_006892	6699965	18	19	Homo sapiens	hg19	20	31389202	31390234	CGACAAGAGGGACATCTCACGGTT	3	GCCATCAAAGTTTCTGCTGCTCA	9	PLUS	ILLUMINA	1.378	false	
DTX2	NM_020892	6637384	8	9	Homo sapiens	hg19	7	76131743	76132782	CCTCCTGGCCATGTACTGCAAC	9	TGTCCCTCCTGCAAAACCATCTATG	4	PLUS	ILLUMINA	1.344	false	
DVL1	NM_004421	6736052	1	0	Homo sapiens	hg19	1	1284281	1278137	ATTCTTCTTTAAGTCCATGGACCAGGAC	1	GTGGTGAAGGAGGAGATCTTTGATGAC	2	MINUS	ILLUMINA	1.962	false	
EP300	NM_001429	6730292	0	1	Homo sapiens	hg19	22	41489064	41513219	CATCTCCGGCCCTCTCGGCGTC	2	TTTTGGCTCTCTATTTGACTTGGAGCAC	1	PLUS	ILLUMINA	1.338	false	
FGF1	NM_001144934	6799688	4	3	Homo sapiens	hg19	5	141980274	141975032	CTTGGCCATGGACACCGACGGGCTTTTATA	1	ATGTTTGTTCCTGGAAAGGCTGGAG	2	MINUS	ILLUMINA	1.583	false	
FGF4	NM_002007	6619194	2	1	Homo sapiens	hg19	11	69588798	69588250	TGAGCAGCAAGGGCAAGCTCTAT	1	TTCTTCACCGATGAGTGCACGTTCAA	1	MINUS	ILLUMINA	1.583	false	
FGFR1	NM_001174067	6763894	6	5	Homo sapiens	hg19	8	38285446	38283742	AATTCAAACCTGACCACAGAATTGGAGG	1	ATCATAATGGACTCTGTGGTGCC	6	MINUS	ILLUMINA	1.6	false	
FOXA2	NM_021784	6877466	1	NA	Homo sapiens	hg19	20	22561867	22561864	GCTTATAAATGTGTATTCTGGCTGCAAGG	1	CAGAGTTCCACAAATCTATATTAAAGTGT	1	MINUS	ILLUMINA	1.727	false	
FZD2	NM_001466	6750540	0	0	Homo sapiens	hg19	17	42636691	42636758	GCACTCGTGGAGGAAGTTCTACACT	1	GGTGAGACCACCGTGTGAGGGA	4	PLUS	ILLUMINA	1.3	false	
FZD3	NM_017412	6678265	6	7	Homo sapiens	hg19	8	28413460	28420341	GGCAGCCTCCACAGATCACGTGAT	1	CGCCCTGCAGTTACAGAGGAAT	7	PLUS	ILLUMINA	1.184	false	
FZD5	NM_003468	6674202	1	0	Homo sapiens	hg19	2	208633993	208633714	TGCTCTTCTCGGCGGGATCCGT	4	CTTTCCCTGGAATCCGAGCCCTAA	1	MINUS	ILLUMINA	1.171	false	
FZD6	NM_001164616	6625204	3	4	Homo sapiens	hg19	8	104330978	104336742	TTGGGATCCGATGGCCTGAGGAGCTTGAAT	1	TACTGTGATGAGACTGTTCCTGTAACT	2	PLUS	ILLUMINA	1.689	false	
FZD7	NM_003507	6816331	0	0	Homo sapiens	hg19	2	202901201	202901263	CCTCTACTGAGAAGTGACCTGGAAGT	1	TTGCAGATTTGGGGCGAGGGGTGATTT	1	PLUS	ILLUMINA	1.882	false	
FZD8	NM_031866	6773460	0	0	Homo sapiens	hg19	10	35928775	35928760	CACCAAGACGCACAAGCTGGAGAA	4	TGGGCCTGTTCACCGTGCTCTACA	1	MINUS	ILLUMINA	1.442	false	
FZD9	NM_003508	6698129	0	0	Homo sapiens	hg19	7	72849243	72849313	CGTGATCCAGGAGGGCCTGGAGAACA	1	CTACTGCTCTACTACTTCGGCATGG	3	PLUS	ILLUMINA	1.69	false	
GATA6	NM_005257	6765770	2	3	Homo sapiens	hg19	18	19757050	19761450	AGCCGGCCCCTCATCAAGCCGCAGAA	1	GGCTTGGATTGTCCTGTGCCAACT	2	PLUS	ILLUMINA	1.453	false	
GDF3	NM_020634	6664652	1	0	Homo sapiens	hg19	12	7848058	7843300	TGTACTTCGCTTTCTCCCAGACCAA	1	GTTTCTTTCTTTACCCAAAGAAAATTTCC	2	MINUS	ILLUMINA	1.723	false	
GLI1	NM_005269	6633250	8	9	Homo sapiens	hg19	12	57861246	57861819	GAGCCAAGCACCAGAATCGGACCCATT	2	CCTGGCTGCACCAAACGCTATA	6	PLUS	ILLUMINA	1.378	false	
GLI2	NM_005270	6709455	1	2	Homo sapiens	hg19	2	121685014	121708859	GAGCCTCATTCTGTCCACGGTGT	3	CGGCAGCCCTGTCATCTCTGACATCT	1	PLUS	ILLUMINA	1.475	false	
GLI3	NM_000168	6785534	4	3	Homo sapiens	hg19	7	42116358	42088278	TTACGATCCATCTCCGATTCCTCCAT	1	GTAGCCCTACGTATCCGGACCT	2	MINUS	ILLUMINA	1.426	false	
HDAC2	NR_033441	6658445	14	13	Homo sapiens	hg19	6	114262886	114262233	CCAAGGACAACAGTGGTGAAAAA	14	AGCAACCCCTGAATTTGACAGTCTC	1	MINUS	ILLUMINA	1.518	false	
IGF1	NM_001111283	6630790	2	1	Homo sapiens	hg19	12	102869425	102813449	TTCGTGTGTGGAGACAGGGGCTTTTAT	1	CTCCAGCAGTCGGAGGGCGCCTCA	1	MINUS	ILLUMINA	1.526	false	
IL6ST	NM_002184	6821932	16	15	Homo sapiens	hg19	5	55238507	55237634	TGCCCAGTGGTCACCTCACACT	22	CAAAAGATCAAATGTATTCAGATGGCA	2	MINUS	ILLUMINA	1.413	false	
ISL1	NM_002202	6665771	4	5	Homo sapiens	hg19	5	50687241	50689353	AGAGTGACATAGATCAGCCTGCTTTTC	1	TCAATTTTTCAGAAGGAGGACCGGG	1	PLUS	ILLUMINA	1.885	false	
JAG1	NM_000214	6847115	4	3	Homo sapiens	hg19	20	10639121	10637091	CATGGAAGGCTGGATGGGCCCCGAATGTAA	1	GCTGCAGTCCTAAGCATGGGTCTT	2	MINUS	ILLUMINA	1.402	false	
JUND	NM_005354	6734162	0	0	Homo sapiens	hg19	19	18391507	18391482	AGCCCGCCGTTGTCGCCCATCGACAT	1	GGAGCGCAAGCGGCTGCGCAACCGCAT	2	MINUS	ILLUMINA	1.298	false	
KAT2A	NM_021078	6619344	10	9	Homo sapiens	hg19	17	40269411	40269178	TAAGGAGTATATCGCCCGCCTCGTCTTT	1	AAGCACAAGACTCTGGCCTTGATCAA	1	MINUS	ILLUMINA	1.899	false	
KRT15	NM_002275	6600621	1	0	Homo sapiens	hg19	17	39674589	39673408	CTTCAAGACCATTGAAGAGCTCCG	7	ACCACCATCGACAACTCCCGGGTCAT	1	MINUS	ILLUMINA	1.622	false	
LIFR	NM_002310	6855616	2	1	Homo sapiens	hg19	5	38530609	38528925	CTAATGAATCAAGTAAATAGCCAGAAAAAG	1	AAGTGTGTAACTAACAATTTGCAAGTG	1	MINUS	ILLUMINA	1.676	false	
MME	NM_007289	6735890	21	22	Homo sapiens	hg19	3	154890378	154898177	TGTGCACAGTCCAGGCAATTTCA	3	TGGGACTTTGCAGAACTCTGCAG	7	PLUS	ILLUMINA	1.256	false	
MYC	NM_002467	6670402	1	2	Homo sapiens	hg19	8	128751231	128752671	TGAGGAGACACCGCCCACCACCA	4	AGGAACAAGAAGATGAGGAAGAAATCG	1	PLUS	ILLUMINA	1.518	false	
MYOD1	NM_002478	6832992	1	2	Homo sapiens	hg19	11	17742497	17742843	GAAGGCGCCTACTACAACGAGG	2	AGAGTGCGGCGGTGTCGAGCCTAGACT	1	PLUS	ILLUMINA	1.234	false	
NANOG	NM_024865	6713367	1	2	Homo sapiens	hg19	12	7945776	7947093	CTCTCCAACATCCTGAACCTCAGCTA	9	GTTCCAGAACCAGAGAATGAAATCTAAGAG	10	PLUS	ILLUMINA	1.73	false	
NCAM1	NM_001242607	6666658	0	1	Homo sapiens	hg19	11	112832316	112832368	CCCAGCCAGCAGATTACAATGCT	5	CAAACTAAGGATTTCATTTGGACTTTGT	1	PLUS	ILLUMINA	1.544	false	
NCSTN	NM_015331	6801812	4	5	Homo sapiens	hg19	1	160320006	160321050	TTGAAGATGAAAATGAAACCAAAGTCATC	1	AACCTGAGTCAGAATGGCTCAGCA	2	PLUS	ILLUMINA	1.607	false	
NEUROD1	NM_002500	6818025	1	0	Homo sapiens	hg19	2	182545222	182543583	ACGAGGAATTCGCCCACGCAGGA	1	CCAAATCGTACAGCGAGAGTGGGCTGAT	1	MINUS	ILLUMINA	1.456	false	
NFATC1	NM_172389	6682609	2	3	Homo sapiens	hg19	18	77193711	77208804	GTCGGCCGGAGGACACCCCATCGT	1	CTGCATGGCTACTTGGAGAATGA	4	PLUS	ILLUMINA	1.183	false	
NOTCH1	NM_017617	6827673	22	21	Homo sapiens	hg19	9	139401766	139401418	TACAAGTGCTCCTGCCCACGGG	3	CTGTGAGATCAACGTGGACGACTGCAAT	1	MINUS	ILLUMINA	1.363	false	
NOTCH2	NM_024408	6670286	4	3	Homo sapiens	hg19	1	120539625	120529696	GACTTCACTTTTGAGTGCAACTGCCT	2	GGAGCACCTGTGAGAGGAATATTGATG	1	MINUS	ILLUMINA	1.956	false	
NOTCH3	NM_000435	6628535	31	30	Homo sapiens	hg19	19	15276186	15273356	GCCATGCTGATGTCAATGCTGTGGAT	1	TGGGCTGCGGCTGTGAACAACGTGGAA	1	MINUS	ILLUMINA	1.752	false	
NOTCH4	NM_004557	6858851	29	28	Homo sapiens	hg19	6	32164105	32163914	GAGCCGATAAAGATGCCCAGGACAA	1	TATTCCTGGCGGCGCGGGAAGGA	1	MINUS	ILLUMINA	1.38	false	
NUMB	NM_001005743	6741921	3	2	Homo sapiens	hg19	14	73833610	73822469	TGTAAAGGGCACAGCCAAGATTCAGA	6	AAAAATTAAAATGAACAAATTACGGCAAAG	1	MINUS	ILLUMINA	1.624	false	
OLIG2	NM_005806	6711104	0	1	Homo sapiens	hg19	21	34398298	34399145	AGGCTTTTCGGAGCGAGCTCCTCAAAT	1	GAAGGAGGACCCTGCGAAAGCT	6	PLUS	ILLUMINA	1.391	false	
PAX6	NM_001604	6739272	8	7	Homo sapiens	hg19	11	31822254	31816321	TATCCGGGGACTTCGGTGCCAG	3	AGGAAGGAGGGGGAGAGAATACCAA	4	MINUS	ILLUMINA	1.3	false	
PDX1	NM_000209	6839459	0	1	Homo sapiens	hg19	13	28494651	28498423	AAAGCTCACGCGTGGAAAGGCCAGT	1	GCGCCTACGCTGCGGAGCCGGAGGAGAA	1	PLUS	ILLUMINA	1.383	false	
POU5F1	NM_002701-2	6776194	2	1	Homo sapiens	hg19	6	31133705	31133478	ATGTGGGGCTCACCCTGGGGGTTCTATTT	5	GGAAGGTATTCAGCCAAACGACCAT	6	MINUS	ILLUMINA	1.667	false	
PPARD	NM_001171818	6803867	6	7	Homo sapiens	hg19	6	35391900	35392133	TCACCGGCAAAGCCAGCCACAC	10	CTTTGTGATCCACGACATCGAGACAT	1	PLUS	ILLUMINA	1.394	false	
PPARG	NM_138712	6648963	4	5	Homo sapiens	hg19	3	12434224	12447405	TGCCTTGCAGTGGGGATGTCTCATAAT	1	ATCAGGTTTGGGCGGATGCCACA	2	PLUS	ILLUMINA	1.567	false	
PSEN1	NM_007318	6696264	4	5	Homo sapiens	hg19	14	73640381	73653599	TCCTGGTGGTTCTGTATAAATACAGGTG	1	GCCTGGCTTATTATATCATCTCTATTGTTG	1	PLUS	ILLUMINA	1.736	false	
PSEN2	NM_012486	6836335	11	12	Homo sapiens	hg19	1	227081792	227083159	ATACCACGCTGGCCTGCTTCGT	5	CTGACCCTCCTGCTGCTTGCTGTGTT	4	PLUS	ILLUMINA	1.317	false	
PSENEN	NM_172341	6717799	1	2	Homo sapiens	hg19	19	36236864	36237359	ATTGAACCTGTGCCGGAAGTACTAC	1	CCTGCCTTTTCTCTGGTTGGTCAACAT	1	PLUS	ILLUMINA	1.865	false	
RB1	NM_000321	6839911	25	26	Homo sapiens	hg19	13	49051510	49054160	TCCAAATTTCAGCAGAAACTGGCAG	7	TTCTACTCGAACACGAATGCAAAAGC	1	PLUS	ILLUMINA	1.867	false	
S100B	NM_006272	6770545	1	0	Homo sapiens	hg19	21	48024929	48022308	AGACCAGGAAGGGGTGAGACAAGGAA	1	CATGGTGGCCCTCATCGACGTTT	2	MINUS	ILLUMINA	1.516	false	
SDAD1	NM_018115	6905261	16	NA	Homo sapiens	hg19	4	76881237	76881232	AAGTTCTGGAAGTTGAGAAAGAAGAGA	4	TGAAAATGATGAAGATGGATGGGAAAG	4	MINUS	ILLUMINA	1.967	false	
SMAD2	NM_005901	6705561	10	9	Homo sapiens	hg19	18	45371714	45368320	TTTGTGAAAGGGTGGGGAGCAGAATA	1	AGGCAGACGGTAACAAGTACTCCTT	1	MINUS	ILLUMINA	1.852	false	
SMAD4	NM_005359	6817285	10	11	Homo sapiens	hg19	18	48603114	48604666	CAGGATCAGTAGGTGGAATAGCTCCA	1	CTGGAATTGGTGTTGATGACCTTCGT	1	PLUS	ILLUMINA	1.923	false	
SMO	NM_005631	6697025	5	6	Homo sapiens	hg19	7	128846398	128848628	CTCATCGTGGGAGGCTACTTCCTCAT	1	TCATGACTCTGTTCTCCATCAAGAGC	1	PLUS	ILLUMINA	1.894	false	
SOX1	NM_005986	6742998	0	0	Homo sapiens	hg19	13	112723934	112724005	GAGACAGAGCCCATTTTCTCCATAA	3	TTTATGTGCATGTTTTATGAGTTCAAAATG	1	PLUS	ILLUMINA	1.583	false	
SOX2	NM_003106	6973159	0	0	Homo sapiens	hg19	3	181430245	181430293	AACCAGAAAAACAGCCCGGACC	16	GTCAAGCGGCCCATGAATGCCTTCAT	10	PLUS	ILLUMINA	1.381	false	
SP1	NM_138473	6622453	4	5	Homo sapiens	hg19	12	53803317	53804737	GCTACAGAGGCACAAACGTACACA	1	TGAGAAGAAATTTGCCTGCCCTGAGT	1	PLUS	ILLUMINA	1.729	false	
STAT3	NM_213662	6751980	20	19	Homo sapiens	hg19	17	40475027	40474491	ACTTTCACTTGGGTGGAGAAGGACAT	1	TGGAACCATACACAAAGCAGCAG	9	MINUS	ILLUMINA	1.6	false	
SUFU	NM_016169	6693347	8	9	Homo sapiens	hg19	10	104375132	104377075	CCGGAGCCCTCATTCCTCTCTGCCTAA	1	AGGCTCCTGCATGGACGGCACTTTA	1	PLUS	ILLUMINA	1.682	false	
T	NM_003181	6856497	8	7	Homo sapiens	hg19	6	166574335	166572075	GTGAGCCACAATGCCAGCCCACCTA	8	CAGTACCCCAGCCTGTGGTCTGTGA	1	MINUS	ILLUMINA	1.563	false	
TCF7	NM_201634	6826773	2	3	Homo sapiens	hg19	5	133473825	133474683	CCTGCACCTGCGGACATCAGCCAGAA	1	AGACCCCTGACCTCTCTGGCTTCTACT	1	PLUS	ILLUMINA	1.722	false	
TERT	NM_198253	6839864	9	8	Homo sapiens	hg19	5	1268644	1266649	ACAAGCTGTTTGCGGGGATTCG	3	CTGCTCCTGCGTTTGGTGGATGATTT	1	MINUS	ILLUMINA	1.421	false	
WNT1	NM_005430	6638607	1	2	Homo sapiens	hg19	12	49373472	49374237	GGCCCCACCTCTTCGGCAAGATCGTCAA	1	CGAGAAACGGCGTTTATCTTCGCTAT	1	PLUS	ILLUMINA	1.755	false	
WT1	NM_024426	6849763	3	2	Homo sapiens	hg19	11	32449506	32439200	CTTTGCTGCTGAGGACGCCCTACA	1	TGACAATTTATACCAAATGACATCCCAGC	1	MINUS	ILLUMINA	1.593	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
ABCG2	NM_004827	6819840	THREE_PRIME	false	15	14	MINUS	GCTTTACCAAATATTCTTCGCCAGTACATGTTGCATAGTTACAAGGATTGTTTCCTGTTGCATT
ACTC1	NM_005159	6632116	CENTER	false	5	4	MINUS	GCTATTGTAAGTTGTTTCATGGATGCCAGCAGATTCCATACCAATGAAGGAGGGCTGGAAGAGTGTCTCAGG
ADAR	NM_015841	6608567	CENTER	false	6	5	MINUS	GACCCCCAACTTTTGCTTGGTAAACGAACTTGGGCTCGTGAGGAGGTCCGGACTGGT
ALDH1A1	NM_000689	6692381	FIVE_PRIME	false	1	0	MINUS	TTGCCACTCACTGAATCATGCCATTCATTGTTTATGAAGATCTTAGTATATTGAATCTTCAAATCGGTGAGTAGGA
ALDH2	NM_000690	6629677	CENTER	false	3	4	PLUS	GGATGGTTTTCCCGTGGTACTTATCAGCCCAGCCGGCATAATACCGGAGACATTTGAGGACCATGTCCAAATCCA
APC	NM_001127510	6843533	FIVE_PRIME	false	3	4	PLUS	CCAGGGAAATTACTGCTATCTAAGTTAAGCTCTTTAAGACGCTCTAATAAATCAATCTGTCCAG
AXIN1	NM_003502	6812087	THREE_PRIME	false	10	9	MINUS	CTCGTCGCTCACTTTCTTGAAGTAGTATCTGTAGCTGCCCTTTTTGGTCAGCAGCTCC
BMP1	NR_033403	6706970	THREE_PRIME	false	13	14	PLUS	TGTGAGTCCACTGCGCACCTCCACGAAGTCGTACTTGCACACATCATTGCCCTCTGTCTCAAAGAAGTCAAACTG
BMP2	NM_001200	6770547	THREE_PRIME	false	1	2	PLUS	GGTTGTTTTCCCACTCGTTTCTGGTAGTTCTTCCAAAGATTCTTCATGGTGGAAGCTGCGCACAGTGTTGGCTCGGCT
BMP3	NM_001201	6598093	THREE_PRIME	false	1	2	PLUS	ATGGTAGCATGATTTGATGGCTTCAAAGACTTTGGCATGGGGAACTGGCATGCTCCA
BTRC	NM_033637	6714783	FIVE_PRIME	false	2	3	PLUS	ACTGTTTCTTGGTTTAAGCAGAGTCTGGCACAGCTGTTGTATGTCTGTCTAAGTGAATTCTTCTCTGGTATTATCTTCC
CCNA2	NM_001237	6736142	FIVE_PRIME	false	2	1	MINUS	TGACATGTCCATAGTATGTGGTGACTCAAAACTACCATCCATTGGATAATCAAGAGGGACC
CCND1	NM_053056	6833728	CENTER	false	2	3	PLUS	TGCCACCATGGAGGGCGGATTGGAAATGAACTTCACATCTGTGGCACAGAGGGCAACGAAGGTCTGCGC
CCND2	NM_001759	6791916	CENTER	false	2	3	PLUS	ACGGTGGGTACATGGCAAACTTAAAGTCGGTGGCACACAGAGCAATGAAGGTCTGAGCAT
CCNE1	NM_001238	6797467	CENTER	false	5	6	PLUS	AAAGGTCTCCCTGTGAAGTTTATAGACTTCACACACCTCCATTAACCAATCCAGAAGAATTGCTCGCATTTTT
CD3D	NM_000732	6784536	THREE_PRIME	false	4	3	MINUS	TACTGAGCATCATCTCGATCTCGGAGGGGCTGATAGACCTGGTCATTCCTCAACAGAGCTTG
CD4	NM_000616	6679411	FIVE_PRIME	false	5	6	PLUS	CTCACAGGTCAAATTTTTCTGGAGCTGAGTGGCTCTCATCACCACCAGGTTCACTTCCTGA
CD44	NM_000610	6794802	FIVE_PRIME	false	0	1	PLUS	ACCTGCAAAGCGGCAGGTTATATTCAAATCGATCTGCGCCAGGCTCAGCGGCACGAGGCAGAGTCCCCAG
CD8A	NM_001145873	6799159	THREE_PRIME	false	8	7	MINUS	ATCTCGCCGAAAGGCTGGGCTTGTCTCCCGATTTGACCACAGGCCGGGGACATTTGCAAACACG
CD8B	NM_172101	6743639	FIVE_PRIME	false	2	1	MINUS	TGGGCAGTGGTGGGAAGGAAATCAACCACACTCAGCTGAGTTCCCTTCCCGAAGGTCAGC
CDC42	NM_001039802	6816991	FIVE_PRIME	false	2	3	PLUS	CCACCAATCATAACTGTGACTGCATAGTTGTCAAAAACAGTCGGTACATATTCCGATGGAAATTTGTTTGTTGTG
CDH1	NM_004360	6722746	FIVE_PRIME	false	1	2	PLUS	AAAATAGGCTGTCCTTTGTCGACCGGTGCAATCTTCAAAATTCACTCTGCCCAGGACGCGGCCTCTCTCCAGGTGGCGCCG
CDH2	NM_001792	6781301	THREE_PRIME	false	14	13	MINUS	TCCACAGTGTCAGGCTGCTGCAGCTGGCTCAAGTCATAGTCCTGGTCTTCTTCTCCTCCACCTTCTTCATCATA
CDX2	NM_001265	6649231	THREE_PRIME	false	2	1	MINUS	ATTTTCCTCTCCTTTGCTCTGCGGTTCTGAAACCAGATTTTAACCTGCCTCTCAGAGAGCCCCAGCGTGGCGGCTAGCTCGGCTT
COL1A1	NM_000088	6730404	THREE_PRIME	false	50	49	MINUS	ATTCAATCACTGTCTTGCCCCAGGCTCCGGTGTGACTCGTGCAGCCATCGACAGTGACGCTGTAGGTG
COL2A1	NM_001844	6655921	CENTER	false	24	23	MINUS	AGCAAGACCACTGGGCCCTCGCTCTCCAGGGGCTCCCTTGGGACCTGCCAGACCATCTTGACCTG
CREBBP	NM_004380	6633710	FIVE_PRIME	false	1	0	MINUS	CATCAGGAAGATCATTTTCCAAGTCAAACAATGATCCAAAATCTGTGCTGTCATTCGCCGAGAAACCGGGCGAGCTGAG
CTNNA1	NM_001903	6739734	THREE_PRIME	false	16	17	PLUS	ATCAAGTTCTTGGCTGCCTGGATCAGGGACATGGCGCTGTCCACCCCAGAGACAACAAGCTCCCCGCCGAG
CTNNB1	NM_001098210	6833435	FIVE_PRIME	false	0	1	PLUS	AAACAGTTGTATGGTATACTTCAAATACCCTCAGGGGAACAGGCTCCTCCCGCCGCG
CXCL12	NM_001178134	6692620	FIVE_PRIME	false	1	0	MINUS	ATCTGTAGCTCAGGCTGACGGGCTTCCCGTCGCTGAGGCAGAGCGCGGTCAGCACG
DHH	NM_021044	6674108	FIVE_PRIME	false	1	0	MINUS	AAAGCGTTCACCCGCTCCTTACAACGCTCGGTCATCAGGCGGTCGGCTCCAC
DLL1	NM_005618	6782624	FIVE_PRIME	false	1	0	MINUS	AACTCCTGCAGCTTCAGTTCGAACACCCCAGAGCTCCAGACCTGACACAGCAAGGCCGAGAGCACCGCCA
DLL3	NM_203486	6690868	CENTER	false	3	4	PLUS	AGAAGCCATGCTCAGGGCTGCAGCCTGCTCGGCACACCAGCGGCGCCTCACATTCGTCCTCGAGCGGT
DNMT3B	NM_006892	6699965	THREE_PRIME	false	18	19	PLUS	TGAGCAGCAGAAACTTTGATGGCATCAATCATCACTGGATTACACTCCAGGAACCGTGAGATGTCCCTCTTGTCG
DTX2	NM_020892	6637384	CENTER	false	8	9	PLUS	CATAGATGGTTTTGCAGGAGGGACACTGCAGACTTCCATCCTTATTGCCGTTGCAGTACATGGCCAGGAGG
DVL1	NM_004421	6736052	FIVE_PRIME	false	1	0	MINUS	GTCATCAAAGATCTCCTCCTTCACCACCCCGAAGTCCTGGTCCATGGACTTAAAGAAGAAT
EP300	NM_001429	6730292	FIVE_PRIME	false	0	1	PLUS	GTGCTCCAAGTCAAATAGAGAGCCAAAATCTGTGCCATCGCTGGCGGACGCCGAGAGGGCCGGAGATG
FGF1	NM_001144934	6799688	FIVE_PRIME	false	4	3	MINUS	CTCCAGCCTTTCCAGGAACAAACATTCCTCATTTGGTGTCTGTGAGCCGTATAAAAGCCCGTCGGTGTCCATGGCCAAG
FGF4	NM_002007	6619194	FIVE_PRIME	false	2	1	MINUS	TTGAACGTGCACTCATCGGTGAAGAAGGGCGAGCCATAGAGCTTGCCCTTGCTGCTCA
FGFR1	NM_001174067	6763894	FIVE_PRIME	false	6	5	MINUS	GGCACCACAGAGTCCATTATGATGCTCCAGGTGGCATAACGGACCTTGTAGCCTCCAATTCTGTGGTCAGGTTTGAATT
FOXA2	NM_021784	6877466	NA	false	1	NA	MINUS	ACACTTTAATATAGATTTGTGGAACTCTGGCCTTGCAGCCAGAATACACATTTATAAGC
FZD2	NM_001466	6750540	FIVE_PRIME	false	0	0	PLUS	TCCCTCACACGGTGGTCTCACCGTGTCGGCTGTTGGTGAGGCGAGTGTAGAACTTCCTCCACGAGTGC
FZD3	NM_017412	6678265	THREE_PRIME	false	6	7	PLUS	ATTCCTCTGTAACTGCAGGGCGTGTACCTGCCATCACGTGATCTGTGGAGGCTGCC
FZD5	NM_003468	6674202	FIVE_PRIME	false	1	0	MINUS	TTAGGGCTCGGATTCCAGGGAAAGGACTCTCCACGGATCCCGCCGAGAAGAGCA
FZD6	NM_001164616	6625204	CENTER	false	3	4	PLUS	AGTTACAGGAACAGTCTCATCACAGTATTGTAATCTGTCACATTCAAGCTCCTCAGGCCATCGGATCCCAA
FZD7	NM_003507	6816331	FIVE_PRIME	false	0	0	PLUS	AAATCACCCCTCGCCCCAAATCTGCAAAGAACTTCTCACTTCCAGGTCACTTCTCAGTAGAGG
FZD8	NM_031866	6773460	FIVE_PRIME	false	0	0	MINUS	TGTAGAGCACGGTGAACAGGCCCAGGCGGATCATCAGCTTCTCCAGCTTGTGCGTCTTGGTG
FZD9	NM_003508	6698129	FIVE_PRIME	false	0	0	PLUS	CCATGCCGAAGTAGTAGAGCAGTAGGAAGACCAGCGTGCAGCCCGTGTTCTCCAGGCCCTCCTGGATCACG
GATA6	NM_005257	6765770	FIVE_PRIME	false	2	3	PLUS	AGTTGGCACAGGACAATCCAAGCCGCCGTGATGAAGGCACGCGCTTCTGCGGCTTGATGAGGGGCCGGCT
GDF3	NM_020634	6664652	FIVE_PRIME	false	1	0	MINUS	GGAAATTTTCTTTGGGTAAAGAAAGAAACCTTGGTCTGGGAGAAAGCGAAGTACA
GLI1	NM_005269	6633250	CENTER	false	8	9	PLUS	TATAGCGTTTGGTGCAGCCAGGGAGCTTACATACATACGGCTTCTCATTGGAATGGGTCCGATTCTGGTGCTTGGCTC
GLI2	NM_005270	6709455	FIVE_PRIME	false	1	2	PLUS	AGATGTCAGAGATGACAGGGCTGCCGCTGAGGGCAGGGGGCCCGTGCACACCGTGGACAGAATGAGGCTC
GLI3	NM_000168	6785534	CENTER	false	4	3	MINUS	AGGTCCGGATACGTAGGGCTACTAGATAAGGCGGAAGTCATATGCAATGGAGGAATCGGAGATGGATCGTAA
HDAC2	NR_033441	6658445	THREE_PRIME	false	14	13	MINUS	GAGACTGTCAAATTCAGGGGTTGCTGAGCTGTTCTGATTTGGTTCCTTTGGTATCTGTTTTTTCACCACTGTTGTCCTTGG
IGF1	NM_001111283	6630790	FIVE_PRIME	false	2	1	MINUS	TGAGGCGCCCTCCGACTGCTGGAGCCATACCCTGTGGGCTTGTTGAAATAAAAGCCCCTGTCTCCACACACGAA
IL6ST	NM_002184	6821932	THREE_PRIME	false	16	15	MINUS	TGCCATCTGAATACATTTGATCTTTTGAATTAAAATTGTGCCTTGGAGGAGTGTGAGGTGACCACTGGGCA
ISL1	NM_002202	6665771	THREE_PRIME	false	4	5	PLUS	CCCGGTCCTCCTTCTGAAAAATTGACCAGTTGCTGAAAAGCAGGCTGATCTATGTCACTCT
JAG1	NM_000214	6847115	CENTER	false	4	3	MINUS	AAGACCCATGCTTAGGACTGCAGCCTTGTCGGCAAATAGCTCTGTTACATTCGGGGCCCATCCAGCCTTCCATG
JUND	NM_005354	6734162	FIVE_PRIME	false	0	0	MINUS	ATGCGGTTGCGCAGCCGCTTGCGCTCCGCCTTGATGCGCTCCTGCGTGTCCATGTCGATGGGCGACAACGGCGGGCT
KAT2A	NM_021078	6619344	CENTER	false	10	9	MINUS	TTGATCAAGGCCAGAGTCTTGTGCTTCGGGTCAAAGACGAGGCGGGCGATATACTCCTTA
KRT15	NM_002275	6600621	FIVE_PRIME	false	1	0	MINUS	ATGACCCGGGAGTTGTCGATGGTGGTGGCCATGATCTTGTCCCGGAGCTCTTCAATGGTCTTGAAG
LIFR	NM_002310	6855616	FIVE_PRIME	false	2	1	MINUS	CACTTGCAAATTGTTAGTTACACACTTCAAATCATGAGGAGCCCCCTTTTTCTGGCTATTTACTTGATTCATTAG
MME	NM_007289	6735890	THREE_PRIME	false	21	22	PLUS	CTGCAGAGTTCTGCAAAGTCCCAATAATCCTGAAATTGCCTGGACTGTGCACA
MYC	NM_002467	6670402	THREE_PRIME	false	1	2	PLUS	CGATTTCTTCCTCATCTTCTTGTTCCTCCTCAGAGTCGCTGCTGGTGGTGGGCGGTGTCTCCTCA
MYOD1	NM_002478	6832992	FIVE_PRIME	false	1	2	PLUS	AGTCTAGGCTCGACACCGCCGCACTCTTCCCGGGCCTGGGTTCGCTGGGCGCCTCGTTGTAGTAGGCGCCTTC
NANOG	NM_024865	6713367	THREE_PRIME	false	1	2	PLUS	CTCTTAGATTTCATTCTCTGGTTCTGGAACCAGGTCTTCACCTGTTTGTAGCTGAGGTTCAGGATGTTGGAGAG
NCAM1	NM_001242607	6666658	FIVE_PRIME	false	0	1	PLUS	ACAAAGTCCAAATGAAATCCTTAGTTTGCAGCATTGTAATCTGCTGGCTGGG
NCSTN	NM_015331	6801812	CENTER	false	4	5	PLUS	TGCTGAGCCATTCTGACTCAGGTTGTGATCTTGATAGCACTGCTTGATGACTTTGGTTTCATTTTCATCTTCAA
NEUROD1	NM_002500	6818025	FIVE_PRIME	false	1	0	MINUS	ATCAGCCCACTCTCGCTGTACGATTTGGTCATGTTTCGATTTCGCCGCGCCTCCTGCGTGGGCGAATTCCTCGT
NFATC1	NM_172389	6682609	FIVE_PRIME	false	2	3	PLUS	TCATTCTCCAAGTAGCCATGCAGCTGCACGATGGGGTGTCCTCCGGCCGAC
NOTCH1	NM_017617	6827673	NA	false	22	21	MINUS	ATTGCAGTCGTCCACGTTGATCTCACAGTGCACACCCTGAGTGCCCCGTGGGCAGGAGCACTTGTA
NOTCH2	NM_024408	6670286	NA	false	4	3	MINUS	CATCAATATTCCTCTCACAGGTGCTCCCTTCAAAACCTGGAAGGCAGTTGCACTCAAAAGTGAAGTC
NOTCH3	NM_000435	6628535	THREE_PRIME	false	31	30	MINUS	TTCCACGTTGTTCACAGCCGCAGCCCAGTGTAAGGCTGATTTCCCAAGCTCATCCACAGCATTGACATCAGCATGGC
NOTCH4	NM_004557	6858851	THREE_PRIME	false	29	28	MINUS	TCCTTCCCGCGCCGCCAGGAATAGCGGCGTCTGCTCCCTGTTGTCCTGGGCATCTTTATCGGCTC
NUMB	NM_001005743	6741921	CENTER	false	3	2	MINUS	CTTTGCCGTAATTTGTTCATTTTAATTTTTACAGCCTGGCTCTGAATCTTGGCTGTGCCCTTTACA
OLIG2	NM_005806	6711104	FIVE_PRIME	false	0	1	PLUS	AGCTTTCGCAGGGTCCTCCTTCCCTCGGACCCGAAAATCTGGATGCGATTTGAGGAGCTCGCTCCGAAAAGCCT
PAX6	NM_001604	6739272	CENTER	false	8	7	MINUS	TTGGTATTCTCTCCCCCTCCTTCCTGTTGCTGGCAGCCATCTTGCGTAGGTTGCCCTGGCACCGAAGTCCCCGGATA
PDX1	NM_000209	6839459	FIVE_PRIME	false	0	1	PLUS	TTCTCCTCCGGCTCCGCAGCGTAGGCGCCGCCTGCCCACTGGCCTTTCCACGCGTGAGCTTT
POU5F1	NM_002701-2	6776194	FIVE_PRIME	false	2	1	MINUS	ATGGTCGTTTGGCTGAATACCTTCCCAAATAGAACCCCCAGGGTGAGCCCCACAT
PPARD	NM_001171818	6803867	FIVE_PRIME	false	6	7	PLUS	ATGTCTCGATGTCGTGGATCACAAAGGGCGCCGTGTGGCTGGCTTTGCCGGTGA
PPARG	NM_138712	6648963	CENTER	false	4	5	PLUS	TGTGGCATCCGCCCAAACCTGATGGCATTATGAGACATCCCCACTGCAAGGCA
PSEN1	NM_007318	6696264	CENTER	false	4	5	PLUS	CAACAATAGAGATGATATAATAAGCCAGGCATGGATGACCTTATAGCACCTGTATTTATACAGAACCACCAGGA
PSEN2	NM_012486	6836335	THREE_PRIME	false	11	12	PLUS	AACACAGCAAGCAGCAGGAGGGTCAGACACAAGCCAATGAGGATGGCCACGAAGCAGGCCAGCGTGGTAT
PSENEN	NM_172341	6717799	CENTER	false	1	2	PLUS	ATGTTGACCAACCAGAGAAAAGGCAGGAAAGCAAACCCCCCCAGGTAGTACTTCCGGCACAGGTTCAAT
RB1	NM_000321	6839911	THREE_PRIME	false	25	26	PLUS	GCTTTTGCATTCGTGTTCGAGTAGAAGTCATTTCTGCCAGTTTCTGCTGAAATTTGGA
S100B	NM_006272	6770545	FIVE_PRIME	false	1	0	MINUS	AAACGTCGATGAGGGCCACCATGGCCTTCTCCAGCTCAGACATCCTCTTCCTTGTCTCACCCCTTCCTGGTCT
SDAD1	NM_018115	6905261	NA	false	16	NA	MINUS	CTTTCCCATCCATCTTCATCATTTTCAATGTCTCTTCTTTCTCAACTTCCAGAACTT
SMAD2	NM_005901	6705561	THREE_PRIME	false	10	9	MINUS	AAGGAGTACTTGTTACCGTCTGCCTTCGGTATTCTGCTCCCCACCCTTTCACAAA
SMAD4	NM_005359	6817285	THREE_PRIME	false	10	11	PLUS	ACGAAGGTCATCAACACCAATTCCAGCAGCAGCTGACAGACTGATAGCTGGAGCTATTCCACCTACTGATCCTG
SMO	NM_005631	6697025	CENTER	false	5	6	PLUS	GCTCTTGATGGAGAACAGAGTCATGACTCCTCGGATGAGGAAGTAGCCTCCCACGATGAG
SOX1	NM_005986	6742998	FIVE_PRIME	false	0	0	PLUS	CATTTTGAACTCATAAAACATGCACATAAAAATAGCATGTTACAAATTTATGGAGAAAATGGGCTCTGTCTC
SOX2	NM_003106	6973159	FIVE_PRIME	false	0	0	PLUS	ATGAAGGCATTCATGGGCCGCTTGACGCGGTCCGGGCTGTTTTTCTGGTT
SP1	NM_138473	6622453	THREE_PRIME	false	4	5	PLUS	ACTCAGGGCAGGCAAATTTCTTCTCACCTGTGTGTGTACGTTTGTGCCTCTGTAGC
STAT3	NM_213662	6751980	THREE_PRIME	false	20	19	MINUS	CTGCTGCTTTGTGTATGGTTCCACGGACTGGATCTGGGTCTTACCGCTGATGTCCTTCTCCACCCAAGTGAAAGT
SUFU	NM_016169	6693347	THREE_PRIME	false	8	9	PLUS	TAAAGTGCCGTCCATGCAGGAGCCTGCCCCTTAGGCAGAGAGGAATGAGGGCTCCGG
T	NM_003181	6856497	THREE_PRIME	false	8	7	MINUS	TCACAGACCACAGGCTGGGGTACTGACTGGAGCTGGTAGGTGGGCTGGCATTGTGGCTCAC
TCF7	NM_201634	6826773	FIVE_PRIME	false	2	3	PLUS	AGTAGAAGCCAGAGAGGTCAGGGGTCTGCAGAGGCCTGTGAACTTGCTTCTGGCTGATGTCCGCAGGTGCAGG
TERT	NM_198253	6839864	CENTER	false	9	8	MINUS	AAATCATCCACCAAACGCAGGAGCAGCCCGTCCCGCCGAATCCCCGCAAACAGCTTGT
WNT1	NM_005430	6638607	THREE_PRIME	false	1	2	PLUS	ATAGCGAAGATAAACGCCGTTTCTCGACAGCCTCGGTTGACGATCTTGCCGAAGAGGTGGGGCC
WT1	NM_024426	6849763	FIVE_PRIME	false	3	2	MINUS	GCTGGGATGTCATTTGGTATAAATTGTCACTGCTGTAGGGCGTCCTCAGCAGCAAAG
